Astro-Fly Healthy, Safe & Top Quality Lighting
1, The healthy & circadian & safe white lighting and RGB lighting to automatically simulate healthy daylight and warm night light!
2, Good lighting makes us a healthy circadian rhythm to improve our life quality and work efficiency during the day, and well relaxed and sleepy at night, certainly we also can select the lighting settings what we ourself like!
3, Quality healthy lighting makes use of a human's non-visual receptors in the eye to entrain the brain to release the appropriate hormones at the appropriate time to create a healthy circadian rhythm all based on the spectrum of light delivered.
4, An super-excellent LED lighting system that generates just the right amount of light to suit our changing environment enabling people to reach peak performance and relaxation!
5, 70-85% energy savings and additional maintenance savings is provided by the 10+ years set it
Astro-Fly:
13+Years Experience, Professional Lighting Solution, Strict Production Inspection! High Quality & Cheapest Price & Fast Delivery & Great Service! Assessed Factory Supplier Independently Verified to Build the Growth on Trust & Friendly Relationship!
LED Panel Light:
100-160lm/W, 80-95Ra, UGR≤19, PMMA LGP, Waterproof IP65, Emergency Function, Dali DT8 CCT Tunable+Dimmable, Microwave Induction, FrameLess/SeamLess, Dual Shinning Panel
Different Installation: Recessed / Surface Mounted / Suspended / Spring Transfer Frame
LED light source advantages of LED Panel Light of Astro-fly LED Light:
1,Green environmental protection: non-polluting, non-ultraviolet, infrared and thermal radiation, is the real green light source;
2,Efficient energy-saving: low-power energy-saving 90%, just ordinary incandescent lamp 1 / 10 power consumption
3,Health Eye: LED are used low-voltage DC power supply, no flicker, no glare, brightness uniformity, lighting effects visually closer to natural light;
4,None of electromagnetic radiation: low-voltage DC drive without any electromagnetic radiation, electromagnetic radiation has now been listed as the world's fourth largest public nuisance;
5,Long life maintenance-free: LED at the correct voltage and environment, time of up to 100,000 hours of continuous use, an ordinary incandescent lamp life of 100 times, and the LED package is tight, and resistant to impact, can not easily be destroyed by outside forces, without fear of accidental damage;
6,Adequate illumination: LED lighting instant start and achieve the rated flux and no switching losses, LED light-emitting angle can be adjusted to meet your variety of lighting needs.
Application of LED Panel Light:
LED panel light aims for the high-end market and is widely used in airport, government building, bank, office building, subway station, upscale hotel, upscale shopping mall, upscale entertainment place, etc. It is gradually replacing the grille light using the T8 fluorescent light source.
LED Emergency Power Supply/Battery Backup:
Emergency Lighting Battery Packs:LIR / Ni-MH - 5-40V;
Build up by LIR / Ni-MH, according to different requirements for combination;
Light power/ Crash time = LED40W≥120min; Charging time: >24h;
Emergency power supply request long charging time with small electric current for battery. As LIR / Ni-MH battery has competitive higher energy density as well as characteristics of over charge, over discharge, high/low temperature resistance, durability, safety and storage, this kind of battery has wide range of uses. It has become the first choice for fire emergency power supply;
Compared with Ni-MH battery and Li battery, LIR is safer and cheaper;
Please discharge the whole electricity of battery before your next charge;
Battery packs should keep the charging status above 24h after discharge. The inverter has the protecting function for battery. Overcharge will not damage the battery. When the battery is fully charged, the charger will convert to trickle charge state in order to neutralize the discharge;
Battery working environmental temperature: -20--60℃;
Consider the using scenario mostly is Emergency security reserve, strongly recommend to check up batter every year and mandatory replace the battery every 3 years and battery performance achieve IEC61951-2008;
Notes, please safe use battery, forbid break up, short circuit, fire or water, etc. Avoid the risk;
Application of Emergency Battery Power Backup:
1.LED emergency power supply includes inverter, battery and connecting wires, with fire, moisture-proof etc. security functions;
2. Adapted to the power 100W LED fluorescent lamp, LED down light, LED flood light, LED panel lamp, LED light source, can emergency lighting when the power cut;
3.On an outer wall of emergency power supply box is installed a detection switch, is convenient for users to understand the working state, check whether the lamps can be normally emergency lighting, full power of emergency lighting , no-load protection;
4. The battery pack has been installed into the emergency power supply, battery capacity, determines the length of time the emergency lighting light source. According to the specific requirements of customers, adjust the battery capacity, satisfy the customer control of emergency lighting time;
5.When power supply normally, inverter make emergency lighting battery group in charging or the standby state; when the earthquake ,struck, explosion, accident or other emergency happened, AC suddenly interrupted, inverter power supply for battery immediately converted to emergency lighting group DC, ensure Lamps lighting and safety ,and red, green, and yellow , three LED lamp beads showed normal as main power, charging, fault status;
6. When battery charging saturation, automatically access to power state, compensate self-discharge, maintain battery life and performance. The matching of different capacity battery, can meet the emergency lighting time 1-5 hours, meet the needs of different situations ,can be used in -20. +60 temperature environment;
7.Strictly accordance with the wiring diagram connection circuit, prohibited without source no-load operation, do not open the cover;
8.The user can check the inverter discharge regularly, but when checking, please cut off the power supply, let it discharge until automatically finished;